ARGUS Stereo-Spectral Imaging System
Main Objectives
Cartographic support of other experiments and next missions
WAOSS a wide-angle stereoscopic TV-camera for 0.,1-0.7 µ m range;
OMEGA, a mapping spectrometer for 0.35-5.2 µ m range.
Main Scientific Objectives
Multiband imaging and photometric studies of the surface with 3D reconstruction of its relief
Atmospheric studies: cloud structures, limb brightness, terminator features
Instrument Description
Main Performance Characteristics
Focal length (mm) 175
Angular resolution (sec of arc/pxl) 8
Spatial resolution (m) from H=300 km 12
Radiometric resolution (bit) 8
Spectral range (µ m) 0.1-1.0
Number of pixels per scanline 5184
Angle of view (degrees) 11.5
Swath width (km) from H=300 km 62
Convergence angle (degrees) 20
Mass (kg) 24
Main Scientific Objectives
Global monitoring of time variations of the surface and atmosphere, in particular, cloud movements, changes due to dust storms, etc.
Instrument Description
Main Performance Characteristics
Focal length (mm) 21.7
Angular resolution (sec of arc/pxl) 64
Spatial resolution (m) from H=300 km 96
Radiometric resolution (bit) 8
Spectral range (µ m) 0.4-0.7
Number of pixels per scanline 5184
Angle of view (degrees) 80
Swath width (km) from H=300 km 496
Convergence angle (degrees) 20
Mass (kg) 7.1
OMEGA - Visible And Infrared Mapping Spectrometer
Main Scientific Objectives
Mapping of major gaseous and solid atmospheric components
Spectral Channels
IR-I (a range of 2.7-5.2 µ m) IR-2 (a range of 1.05-2.7 µ m) VNIR (a range of 0.35-1.05 µ m) Spectral resolution 50 to 100 Angular resolution 4 min. of arc Spatial resolution 0.4 to 4 km Swath width 8.8° Mass 29.1 kg
PFS - Planetary Fourier Spectrometer
Main Atmospheric Science Objectives
Global mapping of winds
Studies of variations of H2O and CO in space and time
Aerosols: optical depth, phase function, size distribution and chemical composition
Main Surface Science Objectives
Mineralogical composition of the surface
Surface condensates
Altimetry
Instrument
Main Performance Characteristics
Channels LW SW Spectral range (µ m) 6-45 1.25-4.5 Spectral resolution (cm-2) 2.3 2.3 Angular resolution (degree) 4 2.6 Spatial resolution (km) from H=300 km 20 15 Mass 35.5 kg
TERMOSCAN - Mapping Radiometer
Main Scientific Objectives
Diurnal and seasonal dynamics of the temperature regime;
Searching for anomalous heat sources;
Thermal studies of the atmosphere.
Main Characteristics
Spectral ranges 0.5-1.0 µ m, 8.0-13 µ m Instantaneous field of view: 1' Scanning angle 6° Scan rate 1 line/sec Surface spatial resolution 0.1-1 km/pixe Temperature sensitivity 0.5° K at T = 240° K Mass 28 kg
SVET - High-Resolution Mapping Spectrophotometer
Main Scientific Objectives
Study of the nature of aerosols by measuring spectral and angular distributions of brightness both above the planetary limb and of certain cloud-covered areas;
TERMOSCAN-2 data conversion into digital form compatible with that of the MORION system.
INSTRUMENT
Maps the surface in 32 lines with the mean resolution (about 1 km at the pericenter) in 8 high-resolution lines (300 m) and 1 low-resolution IR line (3 km)
Pointing mirror permits observations of different areas of the planet
Tracks pass over the planet surface in approximately meridional direction
Main Characteristics
spectral range 260-900 nm and 1.05-27 µ m main detector array As-Ga. 32 and 8 pixels main field of view 32 X (10' X 10') viewing range -X -10° , +65° mass 10 kg power consumption 9 W
SPICAM - Multichannel Optical Spectrometer
Main Scientific Objectives
Airglow spectroscopy to study the structure of the upper atmosphere;
Global distribution of water vapor.
Method
Measurements of airglow spectra.
Instrument
SPICAM-S
IR channel, lambda = 1.8 to 5 µ m, lambda/delta-lambda = 1000
SPICAM-E
H2O band spectrometer, lambda = 936 nm, lambda/delta-lambda = 10,000
Mass = 48.1 kg
UVS-M - Ultraviolet Spectrophotometer
Main Scientific Objectives
Determine deuterium abundance in the Martian atmosphere
Observe high-altitude temperature profile of the atmosphere
Observe the neutral component of the interstellar-interplanetary medium.
Instrument
HI 1215.7 Å (neutral atomic hydrogen)
DI 1215,3 Å (neutral atomic deuterium)
Hel 584 Å (neutral atomic helium)
0I 1304 Å (neutral atomic oxygen)
0II 834 Å (singly-ionized atomic oxygen)
Main Characteristics
power consumption 10 W data rate 137 bit/s mass 9.5 kg
LWR - Long-Wave Radar (GRUNT and PLASMA experiments)
Main Scientific Objectives
GRUNT
PLASMA
Method of Measurements
Main Characteristics
Frequency range 0.17-5 MHz Number of discrete frequencies 56 Frequency modulation period 0.27 s, 1.08 s Frequency deviation 15 kHz Range measurement error 3.5 km Sounding rangeduring soil Sounding 150-3000 km during ionogram recording 150-5000 km Total mass 30.5 kg
PHOTON - Gamma-ray Spectrometer
Main Scientific Objectives
Determination of the abundance of natural radioactive elements (K,U,Th), basic rock-forming elements and minor elements (H, C, Mg, Al, Si, S, Cl, Ca, Ti, Fe)
Method of Measurements
Instrument
Omnidirectional detection unit (BD-2) with a large CsI crystal (785 cm3). It is placed on a solar panel. The use of a large volume crystal permits the abundance of rock-forming elements to be determined with a high accuracy; amplitude analyzer of counts with 4096 channels. It records gamma spectra from BD-1 and BD-2 units as well as spectra from the PGS detection unit with a superpure germanlure crystal.
Main Characteristics:
parameter to be measured energy spectrum of gamma-rays energy range 0.2 to 10 MeV energy resolution at Ev 0.661 MeV: 7.5% data capacity 3 Mbit/revolution mass 20 kg
NEUTRON-S - Neutron Spectrometer
Main Scientific Objectives:
Instrument
The instrument consists of two units of detectors with six neutron counters, and an electronics unit. Neutron counters are built around 3He, the reaction 3He (n,p) 3H + 0.768 MeV is used. The working pressure in the counters is about 7 atm.
Main Characteristics
Energy range 0.01 < E < 0.4 eV 1 < E < 2 keV 0.01 < E < 3 MeV Measurement time 102-103 s Angle of view 45° Minimum detectable water content 0.5 weight % Mass 10 kg
MAK - Quadrupole Mass Spectrometer
Main Scientific Objectives
Measurement of height profiles of the atmospheric ion and neutral composition
Measurement of H+ D+ He+ abundances and the H+/D+ isotope ratio
Measurement and updating of the isotope ratios O17/O18, Ne20/Ne22, Ne20/Ne21, Ar36/Ar38
Measurement of seasonal and diurnal variations of the Martian upper atmosphere and ionosphere
Instrument
Main Characteristics
mode 1 mode 2 atomic mass range 1-6 a.m.u. 1-60 a.m.u. dynamic range sensitivity nmin (cm3) for ions 10-3 10-5 for neutrals 104 for neutrals H2 and H 106 time needed to measure one spectrum 10 s mass 12 kg