ASPERA-S - Energy-Mass Ion Spectrograph and Neutral-Particle Imager
Main Scientific Objectives
Plasma ion composition
Instrument
ASPERA-S consists of:
Ion-Mass Imaging Spectrometer (IMIS)
Particles are detected by "imaging" sensor using a microchannel plate assembly with position sensitive anodes, 32 x 32 (angle x mass) matrix.
Neutral Particle Imager (NPI)
NPI-2, LiF, records secondary ions and electrons generated by neutral particles (E > 10 eV) (LiF target). An electrostatic filter deflects all charged particles with energies less than 300 keV/q.
Scanner Platform
+/-90° , provides full coverage within 4 pi solid angle
Main Characteristics
IMIS NP-1 NP-2
SSD LiF
Energy range 0.5-50 keV 5-300 keV >=10 eV
Energy resolution (Delta-E/E) 0.07 0.36 <1
Angular resolution(degree) 5 X 11.3 5 X 5 5 X 5
Field of view (degree) +/-5 X 360 5 X 320 5 X 360
Geometry factor
(cm2s ster keV/q 10-4 3 X 10-4 3 X 10-4
Mass range (a.m.u.) 1-1012 1-102 (SSD) 1-1012
Mass resolution 1.3-6.4 (hot) < 1 < 1
4.0 - 30 (cold)
Counting rate (s-1) 0.1- l06 0.001-105 0.001-105
Mass 8.8 kg
FONEMA - Fast Omnidirectional Non-Scanning Energy-Mass Analyzer
Main Scientific Objectives
Instrument
Main Characteristics
Energy range 20 eV-8 keV Energy resolution Delta-E/E 0.2 FOV 4 pi Angular resolution (degree) 30 x 60 Geometry factor(cm2 ster) 4.2 X 10-5 Mass range (a.m.u.) 1-30 Mass resolution, M/Delta-M 6 Time resolution 0.1 s Mass 8.8 kg
DYMIO - Omnidirectional Ionospheric Energy-Mass-Spectrometer
Main Scientific Objectives
Method
Parameters of the ionosphere: ion number densities and
ion composition, ion temperature and convective velocity
Parameters of ions leaving the ionosphere, and their
contribution to the ion composition of the magnetosphere
Dynamics of the ionosphere and magnetosphere and their
relationship with the solar wind interaction with Mars
Hardware
Main Characteristics
Field of view 4 pi Sensitivity 10-1 ions/cm3 Time resolution 0.25 s Mass range 1-44 a.m.u. Number density range 10-1-l05 cm-3 Number density accuracy 10% Temperature range 200-10,000 K Temperature accuracy 10% for Ti > 1000 K Velocity accuracy 100 m/s for Vi < 1000 m/s Data flow (max) 1-2 kbit/s Mass 6.1 kg
MARIPROB - Ionospheric Plasma Spectrometers
Main Scientific Objectives
Method
Electron number density
Electron temperature
Ion number density
Mass composition of major components
Full vector of the ion drift velocity
Hardware
2 identical ion energy spectrometers
A set of 28 retarding potential analyzers
Spherical ion probe
A spherical retarding potential analyzer operating in
a floating mode with periodic measurements of integral cold ion energy
spectra
Main Characteristics
Ion, electron number densities, Ni, Ne, 0.1-5 X 105 cm-3
Ion, electron temperature. Ti, Te, < 15,000 K
Cold plasma convection velocity 10 m/s-35 km/s
FOV 4 pi
Mass composition 2-3 major masses (H+, O+,O2+)
Mass 7.9 kg
MAREMF - Electron Analyzer and Magnetometer
Main Scientific Objectives
Hardware
Main Characteristics
Magnetometer Dynamic range +/-32, +/-128 nT Resolution 4 pi T Max sampling rate 100 vectors/s Electron spectrometer E/q range 0.5 eV to 2 keV Field of view 4 pi Spectral resolution 14% Angular resolution 4 x 22 degree Mass 11.3 kg
ELISMA - Wave Complex
Main Scientific Objectives
Identification of instabilities in the ionosphere and magnetosphere
Study of waves of atmospheric origin generated by sand storms and lightning
Global mapping of plasma convection
Distribution of thermal plasma temperature and density to an altitude of 300 km
Dynamic relationship between the upper atmosphere and the lower ionosphere
Hardware
Magnetic field sensors (three orthogonal search coil sensors)
Langmuir probe
High frequency (HF) and mutual impedance (MI) probe
Analyzers of the frequency spectrum of physical parameters to be measured
Microprocessor system
Main Characteristics
Electric field, Ex, Ey, Ez frequency range 0-2 X 105 Hz Magnetic field, Bx, By, Bz frequency range 10-1-2 X 103 Hz Electron number density. Ne Langmuir probe 10-105 cm-3 Mutual impedance probe 1-102 cm-3 Frequency range 0-103 Hz Electron temperature, Te 0.1-10 eV Total Mass 11.48 kg
SLED-2 - Low-Energy Charged Particle Spectrometer
Main Scientific Objectives
Hardware
One electron telescope protected by foil
Main Characteristics
Energy range (12 channels) 20 keV - several MeV Field of view of each, telescope 30° Geometry factor (of each) 0.3 cm2ster Mass 3.3 kg